Jump to content

Welcome To Mopar1973Man.Com LLC

We are privately owned, with access to a professional Diesel Mechanic, who can provide additional support for Dodge Ram Cummins Diesel vehicles. Many detailed information is FREE and available to read. However, in order to interact directly with our Diesel Mechanic, Michael, by phone, via zoom, or as the web-based option, Subscription Plans are offered that will enable these and other features.  Go to the Subscription Page and Select a desired plan. At any time you wish to cancel the Subscription, click Subscription Page, select the 'Cancel' button, and it will be canceled. For your convenience, all subscriptions are on auto-renewal.

Grid Heater Bypass

 

Installing this bypass will allow you to manually control if and for how long you want to run the grid heaters when the ECM is commanding the grid heaters on.  This will reduce the load on the alternator/charging system and in turn reduce the harmful AC voltage.  This bypass will also keep the fault codes P0380 Intake Air Heater Relay #1 Control Circuit and P0382 Intake Air Heater Relay #2 Control Circuit from being set.

 

 image.png.c927bdafed81434ec0c6a4d5e30a9bde.png 

 

Parts needed:

1.  2 micro relays, terminal 87 (5) normally open (NO) with suppressor                                                                                                                

2.  2 5 watt / 20 ohm resistor

3.  1 single pole single throw switch (spst)

4.  2 male bullet and 2 female bullet connectors

5.  2 ring terminals

7.  Rosin core solder

6.  10 female quick connect terminals

8.  Heat shrink

9.  ¼” protective wire cover

10. Electrical tape

 

11. Wire 18 AWG  4 different colors would be nice.

12. Optional    3 ATC fuse holders with 2 amp fuse

13. Something to mount the relays and resistors on.

14. 5 or more  6” zip ties

 

 

          Micro relay

                            image.png.bde304c70684738efd61ba40f95105a8.png 

 

Putting it together

To mount the relays, resistors and fuses I used part of a used relay mount from a Volvo that I found.  It was cut and modified to fit the parts.  

image.png.5504fe9bac0862f2852ca7821af85dbe.png image.png.dadcd6a041157ce064562f4ddeca3320.png

 

I didn’t want to cut the wire harness at the fire wall to access the solenoid trigger wires, yellow/black and orange/black, that goes from the Engine Control Module (ECM) to the grid heater control solenoids.  I ran two wires to each solenoid connecting to the trigger wires with the male bullet connectors.  This sent the trigger signal back to the control relays at terminal 30 (3).  Two more wires were run from terminal 87 (5) of the control relay back to terminal 86 of the grid heater solenoids and connected the wires with the female bullet connectors.

                                     image.png.44bb2327d00c3db49c94d04c188d8cfb.png

 

 

 You can cover the wires from the firewall to the solenoids with the ¼” protective wire cover.

 

                         image.png.962ecd43a8db9ee9a832ab6d54fe4a62.png  

 

I installed the rely/resistor housing  under the dash secured with a sheet metal screw and attached the ground wires to the dash sheet metal.   For power I tapped into the fuse box on the left side of the dash and installed one of the ATC fuse holders and a 3 amp fuse.  The control switch is installed into the left side of the steering column cover; I didn’t want it sticking out of the dash.

image.png.5adf5d4edaf63b05b11c410b56bb7f76.png

 

With the switch in the on position the control relay contacts 30 and 87 close and the grid heaters will operate normally giving heated air to the cylinders.   The switch in the off position the control relay contacts 30 and 87a are closed and the ECM signal goes to the resistors mimicking the grid heater solenoids.  No check engine light and reduced electrical load on the charging system.   The switch can be operated on or off before during or after engine start up.  Another added benefit is if your batteries are weak the grid heaters can be turned off saving power for the starter.

Written by:

J. Daniel Martin, Martin’s Mobile Maintenance

AKA IBMobile

12/21/2018

 

User Feedback

More options...
   1 of 1 member found this review helpful 1 / 1 member

Did this on my truck and I love it, able to control it how I want. Thank you for your time.