We are privately owned, with access to a professional Diesel Mechanic, who can provide additional support for Dodge Ram Cummins Diesel vehicles. Many detailed information is FREE and available to read. However, in order to interact directly with our Diesel Mechanic, Michael, by phone, via zoom, or as the web-based option, Subscription Plans are offered that will enable these and other features.  Go to the Subscription Page and Select a desired plan. At any time you wish to cancel the Subscription, click Subscription Page, select the 'Cancel' button, and it will be canceled. For your convenience, all subscriptions are on auto-renewal.

DTC P0181: FUEL INJECTION PUMP FAILURE

Monitor & Set Conditions

Fuel injection pump operation is monitored with ignition on. DTC will set if a high or low voltage is detected at the fuel temperature sensor signal circuit inside the fuel injection pump controller.

Possible Causes

  • Injection Pump - Engine Running
  • Injection Pump - Engine Off

Testing

1. Turn ignition on with engine off. Using DRBIII(R) scan tool, erase any stored engine DTCs. Start engine and allow the engine to idle for one minute. Using scan tool, read engine DTCs. If DTC P0181 does not exist, go to next step. If DTC P0181 exists, replace fuel injection pump. See appropriate REMOVAL, OVERHAUL & INSTALLATION article.

2. Turn ignition off. Turn ignition on with engine off. Using scan tool, clear engine DTCs. Check for engine DTCs with ignition on and engine off. If DTC P0181 does not exist, the test is complete. If DTC P0181 exists, replace fuel injection pump. See appropriate REMOVAL, OVERHAUL & INSTALLATION article.