P0584 HIGH VOLTAGE DETECTED AT THE SPEED CONTROL VACUUM DRIVER When Monitored and Set Condition: When Monitored: While the engine is running and the Speed control engaged. Set Condition: The Speed Control Vacuum commanded state is on and the feedback state is off. POSSIBLE CAUSES SPEED CONTROL SERVO ASSEMBLY (V36) SPEED CONTROL VACUUM C
- 0 comments
- 1,480 views
-
P0587 LOW VOLTAGE DETECTED AT THE SPEED CONTROL VENT DRIVER When Monitored and Set Condition: When Monitored: While driving and the Speed control is set. Set Condition: This code will set if the voltage detected on the Speed Control Vent circuit at the ECM is different than the expected voltage for 3 seconds. POSSIBLE CAUSES P0595 OR P0596 PRESENT
- 0 comments
- 1,490 views
-
P0588 HIGH VOLTAGE DETECTED AT THE SPEED CONTROL VENT DRIVER When Monitored and Set Condition: When Monitored: While the engine is running and the Speed control is set. Set Condition: The Speed control vent commanded state is on and the feedback state is off. POSSIBLE CAUSES SPEED CONTROL SERVO ASSEMBLY (V35) SPEED CONTROL VENT SHORTED
- 0 comments
- 1,356 views
-
P0595 LOW VOLTAGE DETECTED AT THE S/C BRAKE SWITCH OUTPUT When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The voltage detected on the Cruise Control Servo is above a calibrated value for a calibrated amount on time. POSSIBLE CAUSES SPEED CONTROL SERVO (V32) S/C 12-VOLT SOURCE CIRCUIT OPEN
- 0 comments
- 1,854 views
-
P0596 HIGH VOLTAGE DETECTED AT THE S/C BRAKE SWITCH OUTPUT When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The voltage detected on the Speed Control Servo is below a calibrated value for a calibrated amount on time. POSSIBLE CAUSES SPEED CONTROL SERVO ASSEMBLY (V32) S/C 12-VOLT SOURCE SHORTE
- 0 comments
- 1,764 views
-
P0602 CHECKSUM ERROR When Monitored and Set Condition: When Monitored: While the ignition is on. Set Condition: A deviation between the ECM memory and a stored calibration. POSSIBLE CAUSES FLASH ECM ECM DIAGNOSTIC PROCEDURE Using the DRBIII®, reflash the ECM with the proper calibrati
- 0 comments
- 1,363 views
-
P0602 CONTROL MODULE PROGRAMMING ERROR When Monitored and Set Condition: When Monitored: Continuously Set Condition: The DTC will always light the MIL, and is designed to signal the technician that the controller still has generic software installed. POSSIBLE CAUSES ENGINE AND TRANSMISSION NEED TO BE PROGRAMMED PCM
- 0 comments
- 2,187 views
-
P0604 ECM SOFTWARE ERROR When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: Internal ECM software error. POSSIBLE CAUSES REFLASH ECM ECM DIAGNOSTIC PROCEDURE Using the DRBIII®, reflash the module with latest calibration Was the flash successful?
- 0 comments
- 2,056 views
-
P0604 INTERNAL TCM When Monitored and Set Condition: When Monitored: Continuously with the ignition on. Set Condition: Whenever the PCM detects an internal controller problem. POSSIBLE CAUSES POWER OR GROUND CIRCUIT POWERTRAIN CONTROL MODULE DIAGNOSTIC PROCEDURE Using the schematics as a guide, ins
- 0 comments
- 2,013 views
-
P0605 INTERNAL TCM When Monitored and Set Condition: When Monitored: Continuously with the ignition on. Set Condition: Whenever the PCM detects an internal controller problem. POSSIBLE CAUSES POWER OR GROUND CIRCUIT POWERTRAIN CONTROL MODULE DIAGNOSTIC PROCEDURE Using the schematics
- 0 comments
- 1,845 views
-
P0606 ECM HARDWARE ERROR When Monitored and Set Condition: When Monitored: With the key on or engine running. Set Condition: ECM had detected internal failures. POSSIBLE CAUSES ECM DIAGNOSTIC PROCEDURE Turn the ignition on. NOTE: This DTC is caused by an internal Engine Control Module failure. Repai
- 0 comments
- 1,765 views
-
P0607 ECM INTERNAL FAILURE When Monitored and Set Condition: When Monitored: With the key on or engine running Set Condition: ECM had detected internal failures. POSSIBLE CAUSES ECM DIAGNOSTIC PROCEDURE Turn the ignition on. NOTE: This DTC is caused by an internal Engine Control Module failure. Repa
- 0 comments
- 5,777 views
-
P0613 INTERNAL TCM When Monitored and Set Condition: When Monitored: Continuously with the ignition on. Set Condition: Whenever the PCM detects an internal controller problem, POSSIBLE CAUSES POWER OR GROUND CIRCUIT POWERTRAIN CONTROL MODULE DIAGNOSTIC PROCEDURE Using the schematics as a guide, inspect the wiring
- 0 comments
- 4,164 views
-
P0622 GENERATOR FIELD NOT SWITCHING PROPERLY When Monitored and Set Condition: When Monitored: When the ignition is on. Set Condition: The feedback signal does not match the commanded signal for the voltage regulator. POSSIBLE CAUSES GENERATOR OPEN DRIVER CIRCUIT GEN SOURCE SHORTED TO BATTERY NEGATIVE
- 0 comments
- 9,807 views
-
P0628 LOW VOLTAGE DETECTED AT THE FUEL LIFT PUMP When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The voltage detected on the Fuel Lift Pump is above a calibrated value for a calibrated amount on time. POSSIBLE CAUSES LOOSE CONNECTION GROUND CIRCUIT OPEN LIFT PUMP SHO
- 0 comments
- 2,416 views
-
P0629 HIGH VOLTAGE DETECTED AT THE FUEL LIFT PUMP When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The commanded signal to the lift pump does not match the feedback signal from the lift pump. POSSIBLE CAUSES LOOSE CONNECTION (K62) SUPPLY CIRCUIT SHORTED TO VOLTAGE (K62) SUPPL
- 0 comments
- 5,492 views
-
P0630 VIN NOT ENTERED ERROR When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The VIN was not calibrated into the ECM. POSSIBLE CAUSES VIN NOT CALIBRATED INTO ECM DIAGNOSTIC PROCEDURE Using the DRBIII®, recalibrate the ECM with the proper VIN. Did the DTC P0630 reset?
- 0 comments
- 1,830 views
-
P0633 SKIM SECRET KEY NOT ENTERED When Monitored and Set Condition: When Monitored: While the key is on. Set Condition: The SKIM secret key was not calibrated into the ECM. POSSIBLE CAUSES IMPROPER IGNITION KEY IS BEING USED SKIM DTC'S SKIM NOT CALIBRATED PROPERLY DIAGNOSTIC PROCEDURE
- 0 comments
- 2,518 views
-
P0642 LOW VOLTAGE AT THE #2 SENSOR SUPPLY CIRCUIT When Monitored and Set Condition: When Monitored: With the key on. Set Condition: Voltage detected on the #2 sensor supply circuit is below a calibrated value. POSSIBLE CAUSES FAN CLUTCH ASSEMBLY (F856) 5-VOLT SHORTED TO GROUND (F856) 5-VOLT SUPPLY SHORTED TO ANOTHE
- 0 comments
- 8,436 views
-
P0643 HIGH VOLTAGE AT THE #2 SENSOR SUPPLY CIRCUIT When Monitored and Set Condition: When Monitored: With the key on. Set Condition: Voltage detected on the #2 sensor supply circuit was above a calibrated value. POSSIBLE CAUSES FAN CLUTCH ASSEMBLY (F856) 5-VOLT SHORTED TO VOLTAGE INTERMITTENT CONDITION &
- 0 comments
- 5,319 views
-
P0646 LOW VOLTAGE DETECTED AT THE A/C CLUTCH RELAY When Monitored and Set Condition: When Monitored: When the ignition is on. Set Condition: When the signal from the A/C Clutch output does not match the signal from the A/C Clutch feedback. POSSIBLE CAUSES A/C CLUTCH RELAY LOOSE CONNECTION FUSED BATTERY S
- 0 comments
- 8,539 views
-
P0647 HIGH VOLTAGE DETECTED AT THE A/C CLUTCH RELAY When Monitored and Set Condition: When Monitored: When the ignition is on. Set Condition: When the signal from the A/C Clutch output does not match the signal from the A/C Clutch feedback. POSSIBLE CAUSES LOOSE CONNECTION FUSED BATTERY SUPPLY A/C CLUTCH
- 0 comments
- 2,873 views
-
P0652 LOW VOLTAGE AT THE #1 SENSOR SUPPLY CIRCUIT When Monitored and Set Condition: When Monitored: With the key on. Set Condition: Voltage detected on the sensor supply is below a calibrated value. POSSIBLE CAUSES ECM (F855) #1 5-VOLT SUPPLY SHORTED TO GROUND (F855) #1 5-VOLT SUPPLY SHORTED
- 0 comments
- 13,717 views
-
P0698 ACCELERATOR PEDAL POSITION SENSOR (APPS) SUPPLY VOLTAGE TOO LOW When Monitored and Set Condition: When Monitored: With engine running. Set Condition: Low voltage detected at the APPS signal circuit. POSSIBLE CAUSES (K851) APPS 5-VOLT SUPPLY OPEN APPS HIGH RESISTANCE (K851) 5-VOLT SUPPLY CIRCUIT SHORTED TO
- 0 comments
- 6,944 views
-
P0699 ACCELERATOR PEDAL POSITION SENSOR (APPS) SUPPLY VOLTAGE TOO HIGH When Monitored and Set Condition: When Monitored: While engine is running. Set Condition: High voltage detected at the APPS supply circuit. POSSIBLE CAUSES (K851) 5-VOLT SUPPLY OPEN (K851) 5-VOLT SUPPLY SHORT TO VOLTAGE ECM
- 0 comments
- 2,565 views