Jump to content

Welcome To Mopar1973Man.Com LLC

We are privately owned, with access to a professional Diesel Mechanic, who can provide additional support for Dodge Ram Cummins Diesel vehicles. Many detailed information is FREE and available to read. However, in order to interact directly with our Diesel Mechanic, Michael, by phone, via zoom, or as the web-based option, Subscription Plans are offered that will enable these and other features.  Go to the Subscription Page and Select a desired plan. At any time you wish to cancel the Subscription, click Subscription Page, select the 'Cancel' button, and it will be canceled. For your convenience, all subscriptions are on auto-renewal.

OBDII Error Codes

Everything pertaining to OBDII diagnostics and error code reading and troubleshooting.

132 Cummins articles in this category

  1. Mopar1973Man ·
    P2502 CHARGING SYSTEM ERROR When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: The ECM cycles the voltage regulator in the generator while monitoring for a change in output voltage. If the voltage does not drop when the regulator is off, the fault is set. POSSIBLE CAUSES DIRTY OR LOOSE CONNECTIONS
    Mopar1973Man
    • 0 comments
    • 8,215 views
  2. Mopar1973Man ·
    P2503 CHARGING SYSTEM OUTPUT LOW When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: The battery voltage exceeds target voltage by more than a calibrated value. POSSIBLE CAUSES OTHER DTC'S PRESENT GENERATOR FIELD DRIVER CIRCUIT SHORTED TO GROUND
    Mopar1973Man
    • 0 comments
    • 6,324 views
  3. Mopar1973Man ·
    P2504 CHARGING SYSTEM OUTPUT HIGH When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: Battery voltage is less than 11.5 volts for more than 8 seconds. Battery voltage must exceed 12 volts for more than 5 seconds for fault to become inactive. POSSIBLE CAUSES OTHER DTC'S PRESENT DIRTY OR LOOSE CON
    Mopar1973Man
    • 0 comments
    • 12,533 views
  4. Mopar1973Man ·
    P2509 POWERDOWN DATA LOST ERROR When Monitored and Set Condition: When Monitored: Continuous - key on or key off. Set Condition: Loss of voltage detected at the ECM for a calibrated amount of time. POSSIBLE CAUSES POOR CONNECTIONS AT THE BATTERIES LOW BATTERY VOLTAGE OPEN FUSED B+ TO ECM
    Mopar1973Man
    • 0 comments
    • 3,349 views
  5. Mopar1973Man ·
    P2607 LOW VOLTAGE AT THE #2 INTAKE AIR HEATER RELAY When Monitored: When the ignition is on. Set Condition: When the signal from the #1 intake air heater output does not match the signal from the #1 intake air heater feedback. POSSIBLE CAUSES LOOSE CONNECTION INTAKE AIR HEATER RELAY SIGNAL CIRCUIT OPEN FROM RELAY TO ECM 
    Mopar1973Man
    • 0 comments
    • 7,253 views
  6. Mopar1973Man ·
    P2608 HIGH VOLTAGE AT THE #2 INTAKE AIR HEATER RELAY When Monitored: When the ignition is on. Set Condition: When the signal from the #2 Intake Air Heater output does not match the signal from the #2 Intake Air Heater feedback. POSSIBLE CAUSES LOOSE CONNECTION INTAKE AIR HEATER RELAY SIGNAL CIRCUIT SHORTED TO BATTERY NEGATIVE ECM
    Mopar1973Man
    • 0 comments
    • 2,897 views
  7. Mopar1973Man ·
    P2609 NO VOLTAGE DROP SEEN FROM INTAKE AIR HEATERS When Monitored and Set Condition: When Monitored: First 15 seconds of engine operation. Set Condition: The ECM does not detect a voltage drop on the intake air heater circuit. POSSIBLE CAUSES INTAKE AIR HEATER OPEN INTAKE AIR HEATER GROUND OPEN OPEN BATTERY CABL
    Mopar1973Man
    • 0 comments
    • 3,715 views