OBDII Error Codes
Everything pertaining to OBDII diagnostics and error code reading and troubleshooting.
132 Cummins articles in this category
-
P2502 CHARGING SYSTEM ERROR When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: The ECM cycles the voltage regulator in the generator while monitoring for a change in output voltage. If the voltage does not drop when the regulator is off, the fault is set. POSSIBLE CAUSES DIRTY OR LOOSE CONNECTIONS
- 0 comments
- 8,254 views
-
P2503 CHARGING SYSTEM OUTPUT LOW When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: The battery voltage exceeds target voltage by more than a calibrated value. POSSIBLE CAUSES OTHER DTC'S PRESENT GENERATOR FIELD DRIVER CIRCUIT SHORTED TO GROUND
- 0 comments
- 6,358 views
-
P2504 CHARGING SYSTEM OUTPUT HIGH When Monitored and Set Condition: When Monitored: While the engine is running. Set Condition: Battery voltage is less than 11.5 volts for more than 8 seconds. Battery voltage must exceed 12 volts for more than 5 seconds for fault to become inactive. POSSIBLE CAUSES OTHER DTC'S PRESENT DIRTY OR LOOSE CON
- 0 comments
- 12,673 views
-
P2509 POWERDOWN DATA LOST ERROR When Monitored and Set Condition: When Monitored: Continuous - key on or key off. Set Condition: Loss of voltage detected at the ECM for a calibrated amount of time. POSSIBLE CAUSES POOR CONNECTIONS AT THE BATTERIES LOW BATTERY VOLTAGE OPEN FUSED B+ TO ECM
- 0 comments
- 3,361 views
-
P2607 LOW VOLTAGE AT THE #2 INTAKE AIR HEATER RELAY When Monitored: When the ignition is on. Set Condition: When the signal from the #1 intake air heater output does not match the signal from the #1 intake air heater feedback. POSSIBLE CAUSES LOOSE CONNECTION INTAKE AIR HEATER RELAY SIGNAL CIRCUIT OPEN FROM RELAY TO ECM
- 0 comments
- 7,273 views
-
P2608 HIGH VOLTAGE AT THE #2 INTAKE AIR HEATER RELAY When Monitored: When the ignition is on. Set Condition: When the signal from the #2 Intake Air Heater output does not match the signal from the #2 Intake Air Heater feedback. POSSIBLE CAUSES LOOSE CONNECTION INTAKE AIR HEATER RELAY SIGNAL CIRCUIT SHORTED TO BATTERY NEGATIVE ECM
- 0 comments
- 2,912 views
-
P2609 NO VOLTAGE DROP SEEN FROM INTAKE AIR HEATERS When Monitored and Set Condition: When Monitored: First 15 seconds of engine operation. Set Condition: The ECM does not detect a voltage drop on the intake air heater circuit. POSSIBLE CAUSES INTAKE AIR HEATER OPEN INTAKE AIR HEATER GROUND OPEN OPEN BATTERY CABL
- 0 comments
- 3,726 views